Overview of the Glow-worm Fuelsaver Mk 1 & Mk 2 Boiler Range
The Glow-worm Fuelsaver Mk 1 and Mk 2 range were part of Glow-worm’s early generation of non-condensing boilers, simple, sturdy systems that became a familiar sight in homes across the UK from the late 1970s through the early 1990s. Known for their reliability and straightforward design, these boilers were considered efficient for their time. Many households still have them running today, often tucked away in an airing cupboard or garage, quietly doing their job.
But as solid as they once were, these old Fuelsaver models have now reached a point where running costs, reliability, and safety all fall short of modern standards. They use more gas than necessary, lack the safety features of sealed systems, and finding replacement parts is becoming increasingly difficult.
This guide explains what the Fuelsaver Mk 1 and Mk 2 range were built for, how they perform today, what common faults owners should look out for, and why replacing them through the ECO4 scheme is often the most sensible route.
Key Specifications
The Glow-worm Fuelsaver Mk 1 and Mk 2 range covered a wide selection of models, including:
- Fuelsaver 25-30
- Fuelsaver 30-40
- Fuelsaver 40-50
- Fuelsaver 55-60
- Fuelsaver 60-70
- Fuelsaver 75 series
- And the later “B”, “F”, and “Mk 2” variants such as 30B Mk 2, 40F, 60Mk 2, 75B Mk 2, and 80F.
These boilers were open-flued, wall-hung or floor-standing gas units, designed to heat water through a traditional heat exchanger without condensing technology. They were most commonly fitted in older homes with a tank in the loft and a separate hot water cylinder, known as gravity-fed or open-vented systems.
Key details:
- Boiler type: Heat-only (regular)
- Fuel: Natural gas
- Output range: 25–80kW
- Efficiency: Around 70–75% (non-condensing)
- Installation era: Late 1970s to early 1990s
- Expected lifespan: Around 15 years
For their time, they offered dependable heating for large family homes. The design was simple and easy to service in the 1980s. But most of these systems are now far beyond their intended service life. Even the best-kept models are running at half the efficiency of modern boilers, which is why so many qualify for replacement under ECO4.
Efficiency and Running Costs
When the Fuelsaver Mk 1 and Mk 2 were new, an efficiency rating of 70% was respectable. In practice, that means for every £1 spent on gas, around 30p went straight out of the flue as wasted heat.
Modern condensing boilers, by comparison, achieve 90–94% efficiency. That is a significant improvement. The difference means homeowners with an older Fuelsaver could be losing around a quarter of their heating budget each year.
To put it into perspective:
- A detached home with a Fuelsaver might spend around £1,000–£1,100 per year on gas.
- A semi-detached home might spend around £750.
- A flat or small terrace might spend around £550.
Replacing the old Fuelsaver with a modern condensing boiler could cut bills by up to £300 per year, depending on usage.
These older Glow-worm boilers also lack the safety systems built into modern models. They use open flues, meaning combustion gases are drawn out naturally rather than forced through a sealed flue. That can pose a safety risk if ventilation becomes blocked or the flue deteriorates.
Modern systems, like those fitted under ECO4, include sealed flues, electronic gas valves, and condensate monitoring. All of these make them safer, cleaner, and more efficient to run.
Still, many of these old boilers continue to operate simply because they keep turning on. But quiet operation does not mean they are efficient or safe. The difference is usually felt in your bills rather than in how warm your home feels.
Common Issues and Fixes
The Glow-worm Fuelsaver Mk 1 and Mk 2 boilers were solidly built, but age, corrosion, and outdated components now cause recurring issues. Both generations share similar internals, though the Mk 2 introduced small efficiency and safety improvements. Most surviving units are now more than 30 years old, so mechanical and electrical reliability has declined sharply.
Pilot light keeps going out (Mk 1 and Mk 2 – 40, 50 models)
The smaller Fuelsaver 40 and 50 units often suffer from pilot lights that fail to stay lit. This typically results from a weakened thermocouple, a dirty pilot jet, or a gas valve that no longer maintains stable flow at low pressure. Carbon deposits around the jet restrict gas flow, while age-related wear on the thermocouple stops it from detecting heat correctly. Cleaning or replacing these components may restore function temporarily, but most parts are now discontinued, so recurring failure is common.
Ignition and flame failure (Mk 2 – 50, 60, 70 models)
The Mk 2 introduced a spark ignition system, which tends to degrade over time due to corroded electrodes or broken ignition leads. When the spark becomes weak or inconsistent, the boiler may light and immediately shut down. The issue can also stem from worn gas valves or low inlet pressure. These faults are typical in the mid-range Mk 2 50 and 60 models, where ageing control boards and electrodes struggle to maintain a steady flame.
Overheating and lockouts (Mk 1 and Mk 2 – 70, 80 models)
Larger Fuelsaver boilers like the 70 and 80 generate higher heat loads, which makes them vulnerable to overheating as scale builds in the heat exchanger. Restricted flow, a faulty thermostat, or a failing circulation pump can cause the boiler to overheat and trip the cut-out. Once scale forms, it insulates internal surfaces, forcing the boiler to run hotter and further accelerating wear. These faults are a common sign the system has reached the end of its reliable lifespan.
Kettling noises (All models, particularly Mk 1 60–80)
A loud rumbling or boiling sound during operation is caused by limescale buildup inside the heat exchanger. The Mk 1 range is especially prone to this, as its original copper exchangers were less resistant to scaling. The noise indicates localised boiling, which puts stress on joints and seals. A system flush can reduce the sound, but the buildup usually returns within months, especially in hard water areas.
Leaking or corroded components (Mk 1 and Mk 2 – 70 and 80)
High-output models frequently develop small leaks around the pump housing, heat exchanger joints, or the pressure relief valve. After decades of heating cycles, gaskets and seals lose elasticity, and corrosion eats through copper fittings. Once the heat exchanger itself starts to leak, repair is no longer practical, as replacements have been discontinued. Engineers often advise replacement when multiple small leaks appear at once.
Circulation issues and cold radiators (Mk 2 – 50, 60 models)
When radiators warm slowly or unevenly, it usually means sludge has built up inside the system. The Mk 2’s smaller waterways make it particularly sensitive to flow restrictions. A partial blockage in the pump or return pipework can cause the boiler to short cycle, running inefficiently and failing to heat the property evenly. Power flushing may provide short-term improvement, but without new components, it rarely solves the issue long term.
Thermostat and control faults (Mk 1 and Mk 2 – 80 models)
The mechanical thermostats fitted to the higher-output models often lose calibration or fail entirely after decades of use. This results in overheating or inconsistent temperature control. Original thermostats are obsolete, and retrofitting newer digital controls usually requires full rewiring and adaptation of the boiler’s internal circuitry, which is rarely economical.
Gas valve sticking or failure (All models, more common in Mk 2)
Gas valves across the Fuelsaver series can become stiff or fail to open fully due to internal corrosion. The Mk 2 models, which use electrically operated valves, are especially prone to coil failure from moisture and age. This leads to intermittent ignition or weak flame output. Replacement valves are now discontinued, leaving refurbishment as the only option, which is unreliable and not recommended for long-term use.
Flue and ventilation issues (All models)
Every Fuelsaver Mk 1 and Mk 2 uses an open flue, which depends on proper airflow from the room. Blocked or partially obstructed flues cause incomplete combustion and increase the risk of carbon monoxide. Corroded flue pipes are also a common safety concern. Even if the boiler operates safely, the open-flue design is far less efficient and more vulnerable to draught-related faults than modern room-sealed systems.
General age-related decline (All models)
After decades of use, wear on internal wiring, seals, and connections leads to ongoing faults that are costly to isolate. Replacement parts for these boilers are increasingly unavailable, meaning engineers often use refurbished components that provide only temporary relief. For most households, replacing the Fuelsaver Mk 1 or Mk 2 with a new A-rated boiler is the only practical and cost-effective option.
Repair vs Replacement
Most Fuelsaver Mk 1 and Mk 2 units are now over thirty years old, twice their design life. Even when serviced regularly, they have reached a point where repairs only delay the inevitable.
Typical repair costs include:
- Fan replacement: £200–£300
- Thermostat replacement: £100–£180
- PCB replacement: £250–£400
Once you add annual servicing and occasional call-outs, the running total often reaches £400–£600 per year just to keep the boiler working.
In contrast, replacing your Fuelsaver through the ECO4 scheme can be completely free if your household qualifies. The upgrade includes a brand new A-rated condensing boiler with installation and warranty, all handled by approved installers.
While you can continue to repair an older Fuelsaver, most heating engineers would agree the smarter choice is replacement. You will save on energy, cut future repair bills, and eliminate long-term safety concerns.
Alternatives and Modern Replacements
When replacing a Glow-worm Fuelsaver Mk 1 or Mk 2, the most suitable modern upgrade is often from the Ideal Logic range. These are regular (heat-only) boilers, so they integrate smoothly with existing systems that use a hot water cylinder and tanks. The swap is straightforward, with minimal pipework changes.
Ideal Logic benefits include:
- Over 90% efficiency
- Quieter operation
- Compact design and smaller footprint
- Smart control compatibility
- Long manufacturer warranties
Worcester Bosch boilers are also a trusted choice, but Ideal Logic boilers tend to fit most existing systems more easily because of their similar size and layout, making them a practical and compatible option for homeowners upgrading from the Fuelsaver Mk 1 and Mk 2 range.
Every system installed through ECO4 is an A-rated condensing boiler, so you not only save on gas but gain better safety, comfort, and control.
Free Boiler Grant Eligibility
Because the Glow-worm Fuelsaver Mk 1 and Mk 2 range are non-condensing, all models qualify for potential replacement under the ECO4 boiler grant scheme.
Here is how eligibility typically works.
1. Health Route
If anyone in the home has a health condition made worse by cold living conditions, such as high blood pressure, asthma, COPD, heart conditions, limited mobility, or a suppressed immune system, the property could be eligible under ECO4’s health-based criteria.
Some councils also offer LA Flex, which allows more flexibility for households just outside the standard criteria.
If your home still relies on a Glow-worm Fuelsaver Mk 1 or Mk 2, it is worth checking whether you qualify. Upgrading to a modern boiler under ECO4 improves comfort, reduces bills, and eliminates the safety concerns of older open-flued systems.
2. Low-Income Route
Households with an EPC rating of D–G or those earning below local income thresholds may also qualify, even without benefits.
3. Benefits Route
You will likely qualify if you or someone in your household receives one of the following:
- Universal Credit
- Pension Credit
- Child Tax Credit
- Working Tax Credit
- Income Support
- Income-Based Jobseeker’s Allowance (JSA)
- Income-Based Employment and Support Allowance (ESA)
Check your eligibility today.
Is It Time to Replace Your Glow-worm Fuelsaver Mk 1 & Mk 2 Boiler?
The Glow-worm Fuelsaver Mk 1 and Mk 2 range earned their reputation for reliability, but time has caught up with them. Most are now inefficient, costly to run, and increasingly unsafe by today’s standards.
Replacing them through the ECO4 scheme is straightforward and free for eligible homes. You will gain a modern, efficient boiler that is quieter, safer, and far cheaper to run, all while reducing your household’s energy use.
If your home still has a Glow-worm Fuelsaver Mk 1 or Mk 2, check today to see if you qualify for a free replacement through the ECO4 scheme.
Frequently Asked Questions
They are regular (heat-only) boilers that work with a hot water cylinder and tanks in the loft. They heat water through a simple gas-fired heat exchanger and were designed for open-vented systems common in older UK homes.
The Fuelsaver Mk 1 was produced from the late 1970s, with the Mk 2 following in the early 1980s. Most installations were completed by the early 1990s.
When new, they achieved around 70–75% efficiency. Modern condensing boilers reach over 90%, which means these older models waste roughly a quarter of the gas they burn.
Pilot light issues, ignition failures, kettling noises, leaks, and thermostat faults are among the most common. Many of these problems relate to age and wear rather than one-off defects.
A few components, like seals and thermocouples, can still be sourced through specialist suppliers, but major parts such as fans or PCBs are mostly discontinued. Repairs are becoming increasingly impractical.
The original design lifespan was around 15 years. Most units still in use today are over 30 years old, meaning they have long exceeded that limit.
While they were safe when installed, open-flued boilers depend on proper ventilation. Blocked flues or poor airflow can pose carbon monoxide risks. Modern sealed systems are far safer.
Yes. All Fuelsaver Mk 1 and Mk 2 boilers are non-condensing and automatically qualify under the ECO4 scheme, subject to meeting household criteria.
The Ideal Logic range is widely recommended. It is efficient, reliable, and fits easily in most existing setups, making it an ideal ECO4 replacement for old Fuelsaver units.
What Our Customers Have To Say
Read More Of Our Reviews On Trust Pilot
We’ve had some bad experiences with installers in the past, but Free Energy Savings was a breath of fresh air. They were helpful and patient, answering all of our questions about the ECO4 scheme and making sure we understood how it worked. The installation was done quickly and professionally, and the team was extremely respectful of our home.
- Jessica B
We were a bit unsure about how the ECO4 grant worked, but Free Energy Savings made everything so simple. The team explained every detail of the grant and the benefits from a new boiler installation. When it came time for the installation, they arrived right on schedule and worked hard to get everything set up. What impressed me most was the attention to detail….
- Amelia L
Free Energy Savings exceeded all of our expectations. From the moment we contacted them, they were responsive and informative. The team helped us through the paperwork for the ECO4 grant, which was a big help since we had no idea where to start. The installation crew was friendly, professional, and fast. It’s been a couple of months now, and we’re already…